EN | ÖÐÎÄ

Products Overview



JB COMPRESSOR SERVICES SDN BHD
No. 56, Jalan Mutiara Emas 5/27,
Taman Mount Austin,
81100 Johor Bahru,
Johor, Malaysia.
+607-3554333
+607-3547990
+607-6651699
+6012-7271200

Zero Air Loss Auto Drain (500)

Zero Air Loss Auto Drain (500) Energy Saving Product And Accessories


Advantages

- Zero Air Loss
- Easy Maintenance
- Low Maintenance
- Large Discharge Outlet
- Able to see the condensate level
- No Power Required
- Simple Operations

 
 

Installation & Operation

Connect the condensate outlet to the inlet of the Autodrainlocated at the top through a Strainer as per diagram. Then connect the discharge to the drains. Should the height of the condensate outlet be too low, then connect to the other inlet located at the bottom but remember to install a return line to prevent Air Lock.

As the condensate fills up the chamber, the float will start to rise and thus exposing the discharge outlet. The pressure from the compressed air will push the condensate out through the discharge outlet.

And when the water level drops, the discharge outlet is automatically closed again. Since the water level is always higher than the discharge outlet, there will be no Air Losses.

 

Technical Specification


 
Proposed Installation Location


Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version